In this user interface, you can set the external clock source attributes of the 2M phase-locked source. You can set the output mode, output timeslot, output threshold, failure condition and failure action of the 2M phase-locked source external clock.
In the NE Explorer, click an NE and choose from the Function Tree.
Parameter |
Value |
Description |
|---|---|---|
2M Phase-Locked Source Number |
External Clock Source 1, External Clock Source 2 Displays the serial numbers of the output external clock sources of an NE. |
Indicates the numbering IDs of the outputs from external clock sources. |
External Clock Output Mode |
2MHz, 2Mbit/s Default: 2Mbit/s |
Specifies whether to set the clock signal output mode of the external source. |
External Clock Output Timeslot |
SA4, SA5, SA6, SA7, SA8, ALL |
Specifies whether to set the timeslot occupied by SSM in the output 2M clock signal. For example, if the value is SA4, the SSM is transmitted by using the fourth bit among the eight bits in the first timeslot TS0 of the four consecutive even frames. If the value is SA5, the SSM is transmitted by using the fifth bit among the eight bits in the first timeslot TS0 of the four consecutive even frames. SSM can only be output in 2M Bit/s output mode. |
External Source Output Threshold |
Threshold Disabled, Not Inferior to G.813 SETS Signal, Not Inferior to G.812 Local Clock Signal, Not Inferior to G.812 Transit Clock Signal, Not Inferior to G.811 Clock Signal Default: Threshold Disabled |
Specifies whether to set the quality standard for external source output and stop outputting clocks when the standard is inferior to the preset threshold. |
2M Phase-Locked Source Failure Condition |
AIS, LOF, AIS OR LOF, No Failure Condition Default: No Failure Condition |
Specifies whether to set the conditions for judging whether the 2M phase-locked source fails. If AIS is selected, AIS alarm will cause 2M phase-locked source failed. |
2M Phase-Locked Source Failure Handling |
2M Output S1 Byte Unavailable, Send AIS, Shut Down Output Default: Shut Down Output |
Specifies whether to set the action taken when the 2M phase-locked source fails. When the 2M phase-locked source fails, external clock output is performed according to the parameter setting. |
Forced Output Shutdown |
Enabled, Disabled |