Clock Source Priority Table (WDM)

In this interface, you can set and query parameters related to the clock source priority table.

Navigation Path

In the NE Explorer, select an NE and choose Configuration > Clock > PTP Clock > Clock Source Priority Table from the Function Tree..

Buttons

Button

Description

New

Creates a clock source.

Delete

Deletes a clock source from the clock source priority table.

Moves a clock source upward.

Moves a clock source downward.

Parameters

Table 1 Descriptions of the parameters for Clock Source Priority Table

Field

Value

Description

PTP Clock Source

For example: Internal Clock Source

The PTP clock sources in the list used by the current NE have different priorities according to their sequences, with the uppermost clock source having the highest priority.

PTP Clock Source No.

For example: Company Code: 001882;Supplying Code: FF;NE IP: 23.0.0.0;Interface ID: 43

The PTP clock source number is unique worldwide.

Board

For example: Shelf3(1)-31-52TOG

Sets a PTP board.

Port

For example: 3(RX1/TX1)

Sets the port of a PTP clock source.