In this user interface, when an NE is connected to an external clock source, you can set the interface attributes of the external clock source, so that the NE can extract the external clock properly.
The OptiX OSN 6800 supports the external clock interfaces of 120 ohms and 75 ohms. The external clock interface supports the adaptive algorithm. When both the 120-ohm clock interface and the 75-ohm clock interface exist or none of them exists, the 120-ohm clock interface is selected by priority.
In the NE Explorer, select an NE and then choose from the Function Tree. Click the Basic Attribute tab.
Parameter |
Value |
Description |
|---|---|---|
External Time Interface |
shelf ID(shelf name)-slot number-board name-external clock interface |
Indicates the name of the input interface of the external clock source on the NE. |
Direction |
Ingress, Egress Default: Egress |
Indicates the direction of the external clock source. |
Interface Protocol Type |
1PPS+Time |
Specifies the interface protocol type of the external clock source on the NE. |
Interface Level |
RS422 |
Specifies the interface level according the interface type when the NE is connected to an external clock source. RS422 indicates that the interface type is RJ45. NOTE:
For the Interface Level field, the OptiX OSN 6800 only supports the value RS422. |
PTP Time Level Mode |
Manual Configuration, Automatic Switch |
Indicates the mode for setting the time quality levels of external time interfaces.
|