In this user interface, you can query and set the alarm suppression state and severity for the control channel control plane.
In the NE Explorer, select an NE and choose from the Function Tree, click Control Channel Alarm Suppression and Severity tab.
Field |
Value |
Description |
|---|---|---|
Event |
For example: CPC_CC_DOWN |
Displays alarm events of the control channel control plane. |
Suppress Status |
Suppressed, Not Suppressed |
Sets the suppression status of an alarm. |
Severity |
Critical, Major, Minor, Warning |
Set the severity of the control plane alarm. |
Source |
NE name-shelf ID(shelf name)-slot number-board name-port number(port name) |
Displays the source of a control channel. |
Remote Address |
For example: 1.1.1.179 |
Displays the node ID of the node at the opposite end |
Next Hop Address |
For example: 1.1.1.179 |
Displays the node ID of the source's next hop. If the next hop is the destination node, the next hop address is the same as remote address. |
Administration Status |
Up, Down |
Downindicates that this channel is disabled. Upindicates that this channel is enabled. |
Operational Status |
Up, Down, Config_Send |
Identifies the current status of the LMP protocol. If the Administration Status is Down, the operation status is down. |
Local CCID |
An integer in decimal format For example: 3 |
Displays the control channel number. |
Type |
For example, OSC_D4_D12 For example, SDH_D4_D12 |
Displays the type of the control channel. |