Synchronizing the NE Time with the Web LCT Server Manually

In the case of NEs that do not have the NTP service configured, you need to check whether the NE time is consistent with the Web LCT server time, so that the Web LCT can correctly record the time of alarm generation. Otherwise, manually synchronize the NE time with the time of the Web LCT server. The NE time can be automatically synchronized with the Web LCT server time in batches.

Prerequisites

The synchronous mode of NE time must be set to NM or NULL.

Background Information

Synchronizing the NE time does not affect services. Before synchronizing the NE time, verify that the system time on the Web LCT server is correct. If you want to change the system time, exit the Web LCT to reset the time and then start the Web LCT again.

Procedure

  1. In the NE Explorer, select an NE and choose Configuration > NE Time Synchronization from the Function Tree.