Enabling UNEQ Insertion for a Specified Path

When you need to interrupt a service that is already in operation, you can insert the Unequipped (UNEQ) in the NE path.

Prerequisites

The tributary boards for RTN series NEs, such as the P01 and PH1, must be created.

Context

NOTICE:

This operation may affect services.

Procedure

  1. In the NE Explorer, select a board and choose Alarm > QoS Alarm > UNEQ Insertion Switch from the Function Tree.
  2. Click Query to query the UNEQ insertion status of each Port/Path from the NE.
  3. Set the UNEQ insertion switch for each Port/Path as required.

    NOTE:

    The UNEQ has the two switches, LOS and Path Not Used. When the board detects LOS alarms or that the channel is not used, the service signal code will be inserted with all "0", indicating that the signal is unavailable.

  4. Click Apply.