Enabling the Alarm Monitoring for Lower Order Paths

If you enable the alarm monitoring function for the lower order paths when you configure lower order services in a VC4 higher order path, you can monitor the alarms of an individual lower order path.

Prerequisites

  • The equipment type must be OptiX OSN 1500, OptiX OSN 2500, OptiX OSN 3500, OptiX OSN 7500, or OptiX OSN 7500II.
  • Lower order service (VC3 or VC12) must be configured on the line board.

Context

During the configuration of higher order pass-through cross-connections, enabling alarm monitoring for lower order paths broadcasts services to the lower order section of the cross-connection board. This wastes lower order service resources if lower order services do not need to be monitored.

Procedure

  1. In the NE Explorer, select a line board and choose Alarm > Lower Order Path Alarm from the Function Tree.
  2. Click Query to query the alarm monitoring status of the lower order paths from the NE.
  3. Select Port and VC4.
  4. Set whether to monitor the alarms on the VC3-1, VC3-2 and VC3-3 path.
  5. Set Monitor Status for each VC12 path.
  6. Click Apply.