If you enable the alarm monitoring function for the lower order paths when you configure lower order services in a VC4 higher order path, you can monitor the alarms of an individual lower order path.
Prerequisites
- The equipment type must be OptiX OSN 1500, OptiX OSN 2500, OptiX OSN 3500, OptiX OSN 7500, or OptiX OSN 7500II.
- Lower order service (VC3 or VC12) must be configured on the line board.
Context
During the configuration of higher order pass-through cross-connections, enabling alarm monitoring for lower order paths broadcasts services to the lower order section of the cross-connection board. This wastes lower order service resources
if lower order services do not need to be monitored.
Procedure
- In the NE Explorer, select a line board and choose from the Function Tree.
- Click Query to query the alarm monitoring status of the lower order paths from the NE.
- Select Port and VC4.
- Set whether to monitor the alarms on the VC3-1, VC3-2 and VC3-3 path.
- Set Monitor Status for each VC12 path.
- Click Apply.