The alarms can be categorized according to the Web LCT standards and functions.
The alarms can be categorized into the following six types according to the
Web LCT standards and functions:
- Communication alarms: alarms related to NE communication, ECC communication, and optical signal communication. For example, loss of NE communication and loss of signal.
- Processing alarms: alarms related to software processing and abnormal conditions. For example, equipment bus collision and secondary path check failure.
- Equipment alarms: alarms related to equipment hardware. For example, laser failure and optical port loopback.
- Service alarms: alarms related to the service status and QoS. For example, performance threshold-crossing of the multiplex section, and excessive B2 bit errors.
- Environment alarms: alarms related to the power supply system and equipment room environment (temperature, humidity, access control and so on). For example, the temperature of the power module exceeds a certain threshold.
- Security alarms: alarms related to the security of Web LCT and NEs. For example, an NE user is not logged in.