Handling Impassable Control Channels

Control channels are classified into control channels inside and outside fibers. The control channels inside fibers use D4-D12 bytes to transmit the check information. The control channels outside fibers are seldom used.

Common Causes for Impassable Control Channels

Common causes for impassable optical-layer control channels are listed as follows:
  • The physical fiber between the OSC and FIU is improperly connected.
  • The fiber connection between the FIU and OSC is wrongly configured on the Web LCT.
  • The SD/SF alarm exists at the OSC port.
  • The number of the OSC ports exceeds the limit. (An OSC port should be uniquely mapped to a control channel. A maximum of 40 control channels are allowed to fail in the verification.)
  • The opposite NE is not an ASON NE or the ASON feature is not successfully enabled.
  • The LMP Protocol Status is manually set to Disabled.
  • The point-to-point protocol (PPP) fails because of the bit errors in the CPU channel.
Common causes for impassable electrical-layer control channels are listed as follows:
  • The SD/SF alarm exists at the corresponding port of the TTI.
  • The corresponding server trail for the TTI is not created or is already deleted.
  • The number of the OSC and TTI ports exceeds 40. (An OSC port should be uniquely mapped with a control channel.)
  • The opposite NE is not an ASON NE or the ASON feature of the opposite NE is not successfully enabled.
  • The LMP Protocol Status is manually set to Disabled.
  • The point-to-point protocol (PPP) fails because of the bit errors in the CPU channel.

Procedure