Setting Loopback for the Microwave Link

In the user interface, you can view or set the loopback status of the IF interface or ODU interface at the two ends of a microwave link to locate equipment faults.

Prerequisites

The microwave link must be created.

Context

For more information about the loopback of ODU interface at the two ends of a microwave link, visit Setting a Loopback for an ODU Interface.

For more information about the loopback of IF interface at the two ends of a microwave link, visit Setting a Loopback for an IF Interface.

NOTICE:

The services may be interrupted at the port or on the path where the loopback is performed.

Procedure

  1. Select the NE in the NE Explorer.
  2. ChooseDiagnoses&Maintenance > Radio Link Lookback from the Function Tree.
  3. Select the local IF board.



  4. Select the desired loopback status for the desired object.
  5. Click Apply.
    Then, the dialog box is displayed.
  6. Click OK.