The topic describes how to browse microwave link alarms to obtain the important intermediate frequency information and alarm information of the NEs on both ends of a microwave link.
In the NE Explorer, select a microwave link and choose from the Function Tree.
Button |
Description |
|---|---|
Auto Refresh |
Refreshes the U2000 Web LCT GUI automatically according to the preset time interval to present real-time parameter values in the GUI. |
Parameter |
Value |
Value |
|---|---|---|
NE Name |
For example: NE(9-128) |
Displays the NE name. |
XPIC |
Enabled, Disabled |
Displays the XPIC enabling status. |
ATPC |
Enabled, Disabled |
Displays the ATPC enabling status. |
AM |
Enabled, Disabled |
Displays the AM enabling status. The hybrid radio can ensure the reliable transmission of the E1 services and provide bandwidth adaptively for the Ethernet services when the AM function is enabled. |
E1 Priority |
Enabled, Disabled |
Displays the E1 priority enabling status. |
Full E1 Capacity Range |
For example: 0-75 |
Displays the E1 capacity range of the IF board in full capacity modulation mode. |
IF Channel Bandwidth |
For example: 40M |
Displays the channel spacing of the corresponding microwave link. |
Modulation |
For example: 16QAM-128QAM |
Displays the modulation mode. |
Capacity |
For example: 84-157Mbit/s |
Displays the service capacity. |
Data Service Bandwidth |
For example: 0.492-1.443Mbit/s |
Displays the data service bandwidth. |
Loopback |
Loopback, Non-Loopback |
Displays the loopback status of IF interface. |
Tx Status |
mute, unmute |
Displays the transmission status of ODU. |
Parameter |
Value |
Description |
|---|---|---|
Severity |
Critical, Major, Minor, Warning |
Displays the severity level of the alarm. |
Alarm Name |
For example: CONFIG_NOSUPPORT |
Displays the name of the alarm. |