UNEQ Insertion Switch

You can choose to monitor PDH interface signal loss for a channel as required to trigger UNEQ insertion. During the monitoring, the service of this channel will be interrupted.

Navigation Path

In the NE Explorer, select the board and select Alarm > QoS Alarm > UNEQ Insertion Switch from the Function Tree.

Parameters

Field

Value

Value

Port/Path

For example: 1

Displays the port/path number.

LOS

Disabled, Enabled

Default: Disabled

Sets whether to treat the T_ALOS alarm detected by board as a condition that triggers the UNEQ insertion.

PLOS

Disabled, Enabled

Default: Disabled

Sets whether to treat the P_LOS alarm detected by board as a condition that triggers the UNEQ insertion.

Path Not Used

Disabled, Enabled

Default: Disabled

Sets whether to treat the unused path detected by board as a condition that triggers the UNEQ insertion.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.