Automatic Laser Shutdown

In this user interface, you can enableautomatic laser shutdown, set the on/off period and continuously on-test period.

Navigation Path

In the NE Explorer, click a board and choose Configuration > Automatic Laser Shutdown from the Function Tree.

Buttons

Button

Description

Query

Queries data from the NE.

Apply

Applies configuration data to the NE.

Test

Performs a long-term test for the laser.

Parameters

Field

Value

Description

Optical Interface

  • Equipment that supports the master and slave shelf management: NE name-shelf ID(shelf name)-slot number-board name-port number(port name)
  • Equipment that does not support the master and slave shelf management: NE name-slot number-board name-port number(port name)

Displays the name of an optical interface.

Auto Shutdown

Disabled, Enabled

Only when auto shutdown is set as Enabled, can you set on period, off period and continuously on-test period.

On Period (ms)

For example: 2000

The time to automatically start the laser to test whether optical fiber is normal after the laser is shut down.

Off Period (ms)

For example: 60000

The time for automatic laser shutdown.

Continuously On-test Period (ms)

For example: 90000

The time to manually start the laser to test whether optical fiber is normal after the laser is shut down.


Huawei Proprietary and Confidential