In this user interface, you can enableautomatic laser shutdown, set the on/off period and continuously on-test period.
In the NE Explorer, click a board and choose from the Function Tree.
Button |
Description |
|---|---|
Query |
Queries data from the NE. |
Apply |
Applies configuration data to the NE. |
Test |
Performs a long-term test for the laser. |
Field |
Value |
Description |
|---|---|---|
Optical Interface |
|
Displays the name of an optical interface. |
Auto Shutdown |
Disabled, Enabled |
Only when auto shutdown is set as Enabled, can you set on period, off period and continuously on-test period. |
On Period (ms) |
For example: 2000 |
The time to automatically start the laser to test whether optical fiber is normal after the laser is shut down. |
Off Period (ms) |
For example: 60000 |
The time for automatic laser shutdown. |
Continuously On-test Period (ms) |
For example: 90000 |
The time to manually start the laser to test whether optical fiber is normal after the laser is shut down. |