One-Touch Test

In this user interface, you can perform the acceptance of general NE attributes and current alarms, perform tests, and generate test reports.

Navigation Path

In the NE Explorer, select the NE and choose Diagnosis&maintenance > One-Touch Test from the Function Tree.

Buttons

Button

Description

Start

Starts the acceptance based on the mandatory acceptance items and optional acceptance items that you select, and generates the acceptance report.

Parameters

Field

Value

Description

Mandatory Acceptance Items

Basic NE attributes

Performs the acceptance of general NE attributes and current alarms.

Current NE alarms

Optional Acceptance Items

Radio frequency

Enables the function of testing the radio frequency after you select Radio frequency and a card.

AM switching test

Enables the function of testing the AM switching after you select AM switching test and a card. You need to set the parameter in the drop-down list to Modulation Mode of the Guaranteed AM Capacity.

NOTE:
The prerequisites of testing AM shifts are:
  • The AM function is enabled for the tested microwave link.
  • The weather is favorable.

AMAC switching test

Enables the function of testing the AMAC switching after you select AMAC switching test and a card. You need to set the parameter in the drop-down list to Modulation Mode of the Guaranteed AMAC Capacity.

NOTE:
  • The parameter only applies to RTN 380.
  • The prerequisites of testing AMAC shifts are:
    • The AMAC function is enabled for the tested microwave link.
    • The weather is favorable.

HSB switching test

Enables the function of testing the HSB switching after you select HSB switching test and a protection group.

NOTE:
The prerequisites of testing IF 1+1 switching are:
  • The equipment is configured with IF 1+1 protection.
  • E1 services are configured.

Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.