Physical link aggregation (PLA/EPLA) allows all Ethernet transmission paths in several Integrated IP microwave links connected to the same equipment to be aggregated as a PLA. For MAC users, a PLA works as a single link.
In the NE Explorer, select an NE and choose .
Menu Item |
Description |
|---|---|
Browse Current Alarms |
Displays the browse current alarms window and you can query the current alarms. |
Browse Historical Alarms |
Displays the browse historical alarms window and you can query the browse historical alarms. |
Alarm Suppression |
Displays the alarm suppression dialog box.
|
Browse Performance |
Displays the performance management window where you can browse the current and historical performance data. |
Performance Statistics Management |
Displays the performance statistics management dialog box where you can create or view performance monitoring instances to browse the current or historical performance data. |
Field |
Value |
Description |
|---|---|---|
PLA ID |
For example: 1 |
Displays physical PLA ID. |
PLA Type |
EPLA,PLA |
Sets physical PLA type. EPLA is enhanced PLA. PLA can aggregate only two links. EPLA can aggregate up to four links. Common PLA is performed on IF ports and therefore requires paired slots. EPLA is performed by data switching chips and therefore raises no requirement for slots. |
Main Board |
For example: slot number-board name |
Sets and sets main board. |
Main Port |
For example: port number(port name) |
A main port represents its PLA group.
|
Hardware Status of Main Port |
For example: Abnormal |
Displays the hardware status of main port. |
Link Status of Main Port |
For example: Abnormal |
Displays the link status of main port. |
Work Status of Main Port |
For example: Main Port |
Displays the work status of main port. |
Minimum Active Links |
For example: 1 |
|
Slave Board |
For example: Abnormal |
Sets slave board. |
Slave Port |
For example: Slave Port |
In a PLA group, the ports other than the main port are slave ports.
NOTE:
|
Hardware Status of Slave Port |
For example: Abnormal |
Displays the hardware status of slave port. |
Link Status of Slave Port |
For example: Abnormal |
Displays the link status of slave port. |
Work Status of Slave Port |
For example: Slave Port |
Displays the work status of slave port. |
Field |
Value |
Description |
|---|---|---|
Cascading Status |
Cascaded, Not cascaded |
Displays status of physical PLA. |
PLA ID |
1 |
Displays physical PLA ID. You can create only one PLA on an NE. The default value is 1. |
PLA Type |
PLA, EPLA |
Sets physical PLA type. EPLA is enhanced PLA. PLA can aggregate only two links. EPLA can aggregate up to four links. Common PLA is performed on IF ports and therefore requires paired slots. EPLA is performed by data switching chips and therefore raises no requirement for slots. |
IF Port |
Slot Number-Board Name-Port Number |
Displays the IF port. |
Service Port |
Slot Number-Board Name-Port Number |
Displays the service port. |
Cascade Port |
Slot Number-Board Name-Port Number |
Displays the cascade port. |
NE Role |
Master NE, Slave NE |
Displays the NE role. |
Protection Type |
No NE-Level protection, NE-level LAG protection |
Displays the protection type. |
Minimum Active Links |
1, 2 |
Sets the minimum active links.
|
Active NE |
For example: NE(9-125) |
Displays the active NE. |
Main Board |
For example: slot number-board name |
Sets and sets main board. |
Port |
Slot Number-Board Name-Port Number |
Displays port of the active NE. |
NE |
Local NE, Adjacent NE |
Displays the NE. |
Hardware Status |
For example: Normal |
Displays hardware status of the active NE. |
Link Status |
For example: Normal |
Displays link status of the active NE. |
Running Status |
For example: Normal |
Displays running status of active NE. |
Standby NE |
For example: NE(9-126) |
Displays the standby NE. |
Port |
Slot Number-Board Name-Port Number |
Displays port of the standby NE. |
Hardware Status |
For example: Normal |
Displays hardware status of the standby NE. |
Link Status |
For example: Normal |
Displays link status of the standby NE. |
Running Status |
For example: Normal |
Displays running status of standby NE. |