In this user interface, you can view and set NE attributes, including NE ID, shelf type, and IP address.
In the NE Explorer, select an NE and choose from the Function Tree.
Button |
Description |
|---|---|
Modify NE ID |
Modify the value of NE ID or extended ID.
NOTICE:
This operation may cause communication interruption between the NE and U2000 Web LCT. |
Clear Smoke Alarm |
Clears smoke alarms of an outdoor rack. |
Field |
Value |
Description |
|---|---|---|
Type |
For example: OptiX RTN 620 |
Displays the type of an NE. |
ID |
For example: 1 |
Displays the unique ID of an NE on the NM for identifying an NE, which is the basis of communication between the NM and an NE. |
New ID |
For example: 1 |
Sets the new ID of an NE on the NM for identifying an NE, which is the basis of communication between the NM and an NE. |
Extended ID |
1 to 255 Default: 9 |
For NE ID extension. |
New Extended ID |
1 to 255 Default: 9 |
Sets the new extended ID of an NE,For NE ID extension. |
Name |
For example: NE70 |
Displays the NE name, for the convenience of searching for the NE. |
Remarks |
- |
Enters extra notes of the NE if desired. |
ESN |
For example: ESN001 |
Displays the equipment serial number (ESN). The ESN is identified on the equipment and cannot be set on the U2000 Web LCT. In addition, the ESN is unique globally and can be used to identify the equipment in a network. |
Resource |
For example: Non-ADM |
Displays the information of resource. |
Accredited Capability |
For example: 0*stm1 |
Displays the accredited capability of the equipment. |
Actual Capability |
For example: 0*stm1 |
Displays the actual capability of the equipment. |
Subrack Type |
For example: Standard Shelf |
Displays the shelf type of an NE. |
Gateway Type |
IP Gateway, Serial Port, USB |
Displays the gateway type of an NE decides the mode of communication between the NE and the NM. |
Affiliated Gateway IP Address |
For example: 10.71.82.94 |
Selects the address of the GNE to which the created NE is associated. |
Affiliated Gateway Port |
Default: 1400 |
Displays the port of the GNE to which an NE is associated. |
Outdoor Cabinet Type |
NULL, APM30 AC, APM30 DC, OMB AC, OMB DC |
Sets the type of outdoor cabinet. |
OLS Trigger Flag |
Disabled, Enabled Default: Disabled |
Sets whether to enable the optical layer monitoring function. |
Software Version (VRC) |
For example: V100R005C00 |
Displays the software version of the NE. |
Backplane Bus Mode |
Standard Mode(1G), Extended Mode(2.5G) |
Indicates the interaction rate of NE backplane lines. The interaction rate depends on the chip capabilities on the main control board. |