In this user interface, you can set and query the activation status of connectivity check (CC).
Navigation Path
In the NE Explorer, click the NE and select from the Function Tree. Click the tab.
Cautions
- In case of segment level CC, the segments cannot be crossed or contained in each other.
- In case of end level CC, the ends cannot be crossed or contained in each other.
- The activation command must be issued to the CC source and sink NEs at the same time, with a difference of 3.5 seconds allowed. If the source is not activated in 3.5 seconds after the sink is activated, an alarm may be reported.
- When CC is deactivated, the segment and end attribute is invalid.
- When the service type of the ATM service is the UNIs-NNI, you can set the Segment and End Attribute for Source. When the service type of the ATM service is UNI-UNI, you can set the Segment and
End Attribute for Source and Sink.
Parameters
Table 1 Descriptions of the parameters for CC Activation Status
Field
|
Value
|
Description
|
Source
|
Slot-Board-Port-VPI-VCI
|
Source node.
|
Sink
|
- UNI-UNI: Slot-Board-Port-VPI-VCI
- UNIs-NNI: PW(type)-VPI-VCI
|
Sink node.
The sinks vary with different ATM service types on the NE.
|
Connection Direction
|
Sink, Source
|
It is aimed at one termination point.
As shown in the following diagram, the source and sink directions of point B are:

|
Segment and End Attribute
|
Segment point, Endpoint
|
Sets the range of the link checked by CC.
|
CC Activate Flag
|
Deactivate, Source activate, Sink activate, Source + sink activate
|
Sets CC Activation Flag.
|