Clock Source Reversion

In this user interface, you can query and set the reversion mode and WTR time of clock sources.

Navigation Path

In the NE Explorer, choose Configuration > Clock > Clock Source Switching. Click the Clock Source Reversion tab.

Parameter Description

Table 1 Parameters for clock source reversion

Parameter

Value

Description

NE Name

For example: NE1

Displays the name of an NE.

High-Priority Clock Source Reversion

Auto-Revertive, Non-Revertive

When a higher priority clock source degrades, the NE will automatically switch to a clock source with lower priority. If Auto-Revertive is set, when the high-priority clock source recovers, the NE will automatically switch back to the high-priority clock source. On the contrary, if Non-Revertive is set, the NE will not automatically switch back to the higher priority clock source.

Clock Source WTR Time (min)

0 to 12

Default: 5

Sets a period of time that starts when the signal is detected to be restored and ends when the clock selector is triggered to respond, so as to prevent transient signal restoration from triggering the clock selector to act

Clock Source Hold-Off Time(100ms)

0, 3 to 18

Indicates the hold-off time of a clock source switching event.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.