In this user interface, when the NE is connected to an external clock source, you can set the cable transmission distance to modify the clock synchronization.
In the NE Explorer, select an NE and then choose from the Function Tree. Click the Cable Transmitting Distance tab.
The external time cable is used to connect the external time input equipment with the clock board.
Parameter |
Value |
Description |
|---|---|---|
External Time Interface |
shelf ID(shelf name)-slot number-board name-external clock interface |
Indicates the name of the input interface of the external clock source on the NE. |
Transmitting Direction |
Ingress, Egress |
Specifies the transmission direction of the cable of the external clock source. NOTE:
|
Transmitting Distance Mode |
Length, Time Default: Length |
Specifies the mode of measuring the cable transmission distance of the external clock source. |
Transmission Length (m) |
0 to 300 Default: 0 |
Specifies the cable transmission length of the external clock source. Specify the value of the parameter as required, to modify the clock synchronization. NOTE:
This parameter is valid only when the Transmitting Distance Mode parameter is set to Length. |
Transmission Delay (ns) |
0 to 1350 |
Specifies the cable transmission time of the external clock source. Specify the value of the parameter as required, to modify the clock synchronization. NOTE:
This parameter is valid only when the Transmitting Distance Mode parameter is set to Time. |