Configuring the NMS Port on an NE

By default, an NE can access the NMS or another NE through its Ethernet network management port or NE cascading port, with the port working mode being auto-negotiation.

Prerequisites

You are an NMS user with "Operator Group" authority or higher.

Background Information

  • It is recommended that the LCT accesses an NE through Ethernet ports.
  • If you need to initialize an NE or perform software loading by using the LCT, the LCT needs to access the NE through Ethernet ports.

Procedure

  1. In the NE Explorer, select the NE from the Object Tree and then choose Communication > Access Control from the Function Tree.
  2. Select Enable Ethernet Access. Then, the NE allows NMS access through its Ethernet ports.



    NOTE:
    To disable the Ethernet port-based access function, deselect Enable Ethernet Access.

  3. Click Apply.
    A confirmation dialog box is displayed.
  4. Click OK. Close the displayed operation result dialog box.
  5. Set Work Mode and Enabled/Disabled of the Ethernet network management port and NE cascading port on the system control, switching, and timing board.



  6. Click Apply.

Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.