Performing NE ID-based Traceroute Test

You can perform an NE ID-based traceroute (ECC traceroute) test on NEs to check the communication between two NEs, find the transit NEs between them, and locate a fault. From the test result, you can learn transit nodes and the communication status between the two NEs.

Prerequisites

  • This function is applicable to the OptiX OSN 500/550/580/1500/2500/3500/7500 V100R010C02 or later.

Context

  • The traceroute test for the IP network serves to test the communication between two NEs only on the IP network. If the NEs belong to the ECC network, the test cannot be performed. The ECC traceroute test can be directly performed based on NE IDs to check the communication between two NEs across ECC and IP networks.

Procedure

  1. In the NE Explorer, select an NE and choose Communication > NE ECC Link Management from the Function Tree.
  2. In the NE ECC Link Management Table window, click Reachability Test and choose Traceroute from the drop-down list.
  3. In the Traceroute dialog box, set Target NE and other parameters.

  4. Click Start Test.
  5. View the test result in the Test Result area.

Follow-up Procedure

If the traceroute test between two NEs is broken, check the network connectivity and service configuration. Perform the test again after troubleshooting.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.