To suppress alarms of a specified board or port, you can directly perform the relevant operations to the board in the NE Explorer. If you suppress a certain alarm of a specified board or a port, the alarm is not reported to the NE or to
the U2000 Web LCT. You can suppress the unimportant alarms.
Procedure
- In the NE Explorer, select a board and choose from the Function Tree.
- Select a port from the Monitored Object drop-down list in the right-hand pane.
NOTE: You can select all ports of a board by selecting the board in the Monitored Object.
- Set the Status of the alarms that need to be suppressed to Suppressed.
NOTE: If you have already created an alarm template for a board, click Use Template to select a suitable template.
- Optional: To restore to the default settings, click Default.
- Click Apply.
Result
- After an alarm is suppressed, the board does not monitor the alarm.
- After an alarm is suppressed, the U2000 Web LCT does not clear the reported alarms, until an alarm cleared notification is received.