Suppressing Alarms of a Board or Port

To suppress alarms of a specified board or port, you can directly perform the relevant operations to the board in the NE Explorer. If you suppress a certain alarm of a specified board or a port, the alarm is not reported to the NE or to the U2000 Web LCT. You can suppress the unimportant alarms.

Procedure

  1. In the NE Explorer, select a board and choose Alarm > Alarm Suppression from the Function Tree.
  2. Select a port from the Monitored Object drop-down list in the right-hand pane.

    NOTE:

    You can select all ports of a board by selecting the board in the Monitored Object.

  3. Set the Status of the alarms that need to be suppressed to Suppressed.

    NOTE:

    If you have already created an alarm template for a board, click Use Template to select a suitable template.

  4. Optional: To restore to the default settings, click Default.
  5. Click Apply.

Result

  • After an alarm is suppressed, the board does not monitor the alarm.
  • After an alarm is suppressed, the U2000 Web LCT does not clear the reported alarms, until an alarm cleared notification is received.