In this user interface, you can query and set auxiliary parameters.
In the NE Explorer, select from the Function Tree. Select Auxiliary tab.
Auxiliary attribute configuration items supported by overhead boards of different equipment vary slightly from one another.
| Button | Description |
|---|---|
| Query | Queries the current configurations of various parameters from the NE. |
| Apply | Applies the configurations. |
Parameter |
Value |
Description |
|---|---|---|
| Subnet No. Length | 1, 2 Default: 1 |
The Subnet No. Length parameter specifies the length of the subnet number of the orderwire subnets if the entire network is divided into multiple orderwire subnets. NOTE:
When the Subnet NO. Length is set to 1, the Subnet of the Optical Interface Subnet No. is in the range of 0 to 9. When the Subnet NO. Length is set to 2, the Subnet of the Optical Interface Subnet No. is in the range of 0 and 10 to 99. |
First Communication Port |
RS232, RS422 |
Selects the first data communication port for SDH NNI connection to achieve the communication with the opposite end of the SDH NNI orderwire. |
First Phone Port |
F1 port, Phone2, Phone3 |
Selects the first phone port for the SDH NNI orderwire. |
Second Communication Port |
RS232, RS422 |
Selects the second data communication port for SDH NNI connection to achieve the communication with the opposite end of the SDH NNI orderwire. The first and second SDH NNI connections are independent of each other. |
Second Phone Port |
F1 port, Phone2, Phone3 |
Selects the second phone port for the SDH NNI orderwire. |