In this user interface, you can set orderwire phone before running the equipment. You can set call waiting time, dialing modes, conference call numbers, orderwire phone numbers, and orderwire phone ports.
In the NE Explorer, click the NE and select from the Function Tree. Click the General tab.
Parameter |
Value |
Description |
|---|---|---|
| Call Waiting Time (s) | 1-9 Default: 9 |
The Call Waiting Time (s) parameter specifies the timeout period of searching an orderwire route. If the period of searching an orderwire route exceeds the specified value, the orderwire phone changes to the busy tone status. |
Dialing Mode |
Pulse, Dual-Tone Frequency Default: Dual-Tone Frequency |
Displays the orderwire dialing mode. |
| Conference Call | 100-99999999 | The Conference Call parameter specifies the phone numbers of networkwide orderwire calls. |
Phone 1, Phone 2, Phone 3 |
100-99999999 | The Phone parameter specifies the phone numbers of orderwire addressing calls.
An addressing call refers to a point-to-point call. The overhead supports a maximum of 3-channel orderwire phone number. As some of the equipment support Phone1 only, Phone2 and Phone3 are not available. When the value is null, after the configuration is delivered, the corresponding data on NEs remains unchanged instead of being cleared. |
Selected Orderwire Ports |
|
Selects the line board port for orderwire transmission. |
| Available Orderwire Ports | Available Orderwire Ports Default: Bid-BidType-PortID |
The Available Orderwire Ports parameter specifies whether the optical interface is used to make orderwire calls. |