In this user interface, you can perform line monitoring operations, such as querying the line status, synchronize the test data, and carry out different types of tests in either the in-service mode or the out-of-service mode. You can also view and analyze the test result.
Button |
Description |
|
|---|---|---|
Query Line Status |
Queries the current working status of a line. |
|
Synchronize Test Data |
Synchronizes the test data between the U2000 Web LCT and NE. |
|
View Current Test Result |
Views middle test result of the line when it is in the Test Status. |
|
View Test Result |
Views the test record of a line. |
|
In-Service Mode |
Start Comparison Test in Single-Test Mode |
Starts the comparison test in single-test mode for a line. |
Start Manual Test |
Starts the manual test for a line. |
|
Start Baseline Collection Test |
Starts the baseline collection test.
NOTE:
To provide reference for comparison tests, alerts, and alarms, you need to collect the baseline. |
|
Start Comparison Test in Periodic Mode |
Starts the comparison test in periodic mode. |
|
Stop the Test |
Stops the test that is carried out currently. |
|
Baseline Management |
Manages the baseline data, including the upload, display, setting, and deletion of the baseline. |
|
Test Parameter Management |
Sets or queries line test parameters. |
|
Line Test Data Analysis |
Displays and analyzes the test data. |
|
Repeater Test Data Analysis |
Displays and analyzes the repeater test data. |
|
Gain Report |
Queries the gain of each repeater on a line within a certain period in a report. |
|
Event Report |
Queries the type of each event and the locations where the events occur on a line in a report. |
|
Out-of-Service Mode |
Start Comparison Test in Single-Test Mode |
Starts the comparison test in single-test in-service mode for a line. |
Start Manual Test |
Starts the manual test in in-service mode for a line. |
|
Start Baseline Collection Test |
Starts the baseline collection test. |
|
Start Fast Fault Location Test |
Start fast fault location test. |
|
Stop the Test |
Stops the test that is carried out currently. |
|
Baseline Management |
Manages the baseline data, including the upload, display, setting, and deletion of the baseline. |
|
Test Parameter Management |
Sets or queries line test parameters. |
|
Line Test Data Analysis |
Displays and analyzes the test data. |
|
Gain Report |
Queries the gain of each repeater on a line within a certain period in a report. |
|
Event Report |
Queries the type of each event and the locations where the events occur on a line in a report. |
|
Menu Item |
Description |
|---|---|
View Details of the Line |
Displays details of the boards, fiber parameters, and remarks of a line. |
Parameter |
Value |
Description |
|---|---|---|
Line ID |
For example: 1 |
Indicates the ID of a line. |
Line Monitoring Unit |
For example: 6-LMU-1(IN/OUT 01) |
Indicates the line monitoring unit. |
Line Access Unit |
For example: 5-LMI-2(IN/OUT 02) |
Indicates the line access unit. |
LMU at Source |
For example: NE9-8-B2LMU-1(IN/OUT) |
Indicates the monitoring unit at the source of a line. |
LMI at Source |
For example: NE9-10-B2LMI-2(RM/TM) |
Indicates the access unit at the source of a line. |
LMU at Sink |
For example: NE19-1-B2LMU1-1(IN/OUT) |
Indicates the monitoring unit at the sink of a line. |
LMI at Sink |
For example: NE19-5-B2LMI-1(RM/TM) |
Indicates the access unit at the sink of a line. |
Direction |
Positive, Reverse |
Indicates the direction of the line. |
Probe Light Band Type |
For example: C |
Indicates the band type of the probe light from LMU boards. |
Probe Light Wavelength NO./Wavelength (nm)/Frequency (THz) |
For example: 1/1529.16/196.050 |
Indicates the wavelength ID, wavelength, and frequency of the probe light from LMU boards. |
Loading Light Band Type |
For example: C |
Indicates the band type of the compensation light from LMU boards. |
Loading Light Wavelength NO./Wavelength (nm)/Frequency (THz) |
For example: 1/1529.16/196.050 |
Indicates the wavelength ID, wavelength, and frequency of the compensation light from LMU boards. |
Remarks |
- |
Indicates the remarks of the line. |
Span ID |
For example: 2 |
Indicates the ID of a span. |
Current Working Status |
Idle Status, Test Status, Waiting Status, BU Switching Status |
Indicates the working status of the line. NOTE:
If a test is being carried out on the line, the current working status is displayed as Test Status. Otherwise, the current working status is displayed as Idle Status. |
Test Status at Source |
For example: Test Status |
Indicates the test status at the source of a line. |
Test Status at Sink |
For example: Test Status |
Indicates the test status at the sink of a line. |
Test Mode |
In-Service Test, Out-of-Service Test |
Indicates the test mode. |
Smooth Filter Status |
Open, Close |
Specifies whether to enable smooth filter. |
Communication Detect |
Open, Close |
Specifies whether to detect communication status. |
Test Type |
Comparison Test in Single-Test Mode, Manual Test, Baseline Collection Test, Comparison Test in Periodic Mode, Fast Fault Location Test |
Indicates the test type. |
Start Time |
For example: 2008-04-30 10:50:25 |
Indicates the start time of a test. |
Remaining Time |
For example: 10:50:25 |
Indicates the remaining time to complete a test. |
Test progress |
For example: 50% |
Indicates the test progress. |
Scheduled Refresh |
Open, Close |
Specifies whether the scheduled refresh function is enabled. |
Attenuation Coefficient |
0.15 to 0.30 |
Indicates the attenuation coefficient of the span. |
Fiber/Cable Length\(km\) |
45.0 to 120.0 |
Indicates the fiber/cable of the span. |
Number of Repeaters |
1-239 |
Indicates the number of repeaters. |
Number of Spans |
2 to 240 |
Indicates the number of spans. NOTE: