In this user interface, you can create, activate, delete, and modify a submarine cable line, and set fiber parameters for the line.
Button |
Description |
|---|---|
Query |
Queries the information and fiber parameter settings of a submarine cable line. |
New |
Creates a line. |
Activate |
Activates a line. |
Modify |
Modifies a line. |
Delete |
Deletes a line. |
Apply |
Applies configurations to NEs. |
Menu Item |
Description |
|---|---|
Modify Remarks |
Modifies the remarks on a line. |
Parameter |
Value |
Description |
|---|---|---|
Line ID |
For example: 1 |
Indicates the ID of a line. |
Source NE |
For example: NE3 |
Specifies the source NE for the bidirectional line to be created. |
Sink NE |
For example: NE4 |
Specifies the sink NE for the bidirectional line to be created. |
Line Monitoring Unit |
For example: 6-LMU-1(IN/OUT) |
Indicates the monitoring unit. |
Line Amplifier Unit |
For example: 3-LOA-1(BAI/BAO) |
Indicates the amplifier unit for a line. |
Line Selection Unit |
For example: 8-LSU-1(IN/OUT) |
Specifies the line selection unit. |
Line Access Unit |
For example: 5-LMI-2(RM/TM) |
Indicates the access unit for a line. |
Line Access NE |
For example: NE3 |
Indicates the NE where the line access unit is located. |
LMU at Source |
For example: 9-B2LMU-1(IN/OUT) |
Specifies the monitoring unit at the source of a line. |
Line Amplifier Unit at Source |
For example: 2-B2LAS-1(RI1/TO1) |
Specifies the amplifier unit at the source of a line. |
LMI at Source |
For example: 12-B2LMI-1(RC/TC) |
Specifies the access unit at the source of a line. |
Remarks |
N/A |
Specifies the remarks on a line. |
Probe Light Band |
For example: C |
Specifies the band type of the probe light from LMU boards. |
Probe Light Band/Wavelength NO./Wavelength (nm)/Frequency (THz) |
For example: C/1/1529.16/196.050 |
Specifies the band type, wavelength ID, wavelength, and frequency of the probe light from LMU boards. |
Load Light Band |
For example: C |
Specifies the band type of the compensation light from LMU boards. |
Load Light Band/Wavelength NO./Wavelength (nm)/Frequency (THz) |
For example: C/1/1529.16/196.050 |
Specifies the band type, wavelength ID, wavelength, and frequency of the compensation light from LMU boards. |
LMU at Sink |
For example: 9-B2LMU-1(IN/OUT) |
Specifies the monitoring unit at the sink of a line. |
Line Amplifier Unit at Sink |
For example: 2-B2LAS-1(RI1/TO1) |
Specifies the amplifier unit at the sink of a line. |
LMI at Sink |
For example: 12-B2LMI-1(RC/TC) |
Specifies the access unit at the sink of a line. |
Repeater Number |
For the SLM 1630 V100R001: 1 to 239 For the SLM 1630 V100R002: 0 to 299 |
Specifies the total number of repeaters on a line. |
Number of Spans |
For the SLM 1630 V100R001: 2 to 240 For the SLM 1630 V100R002: 1 to 300 |
Indicates the total number of spans. NOTE:
Number of Spans changes according to Repeater Number and cannot be set. |
Span ID |
For example: 2 |
Displays the ID of a span. |
Fiber/Cable Type |
For example: G.652 |
Displays or enables you to set the fiber type of a span. |
Refractive Index |
1.300 to 1.600 |
Displays or enables you to set the fiber refractive index of a span. |
Attenuation Coefficient |
0.15 to 0.30 |
Displays or enables you to set the fiber attenuation coefficient of a span. |
Fiber Length(km) |
For the SLM 1630 V100R001: 45.0 to 400.0 For the SLM 1630 V100R002: 35.0 to 400.0 |
Displays or enables you to set the fiber length of a span. |
Number of Underwater Devices |
0 to 50 |
Indicates the number of underwater devices (BU and OEQ) on the created line. OEQ is short for optical equalizer. |
Tab Page |
Description |
|---|---|
Cross-Span Management |
Displays cross-span information about submarine cable lines. For details, see Cross-Span Management. |
Underwater Device Parameters |
Displays information about underwater devices on submarine cable lines. For details, see Underwater Device. |