In this user interface, you can set test parameters for the manual test and line baseline collection test.
Button |
Description |
|---|---|
Query |
Queries the current test parameters. |
Set |
Applies the test parameters. |
Parameter |
Value |
Description |
|---|---|---|
Pulse Width(us) |
For In-Service Mode,
For Out-of-Service Mode,
|
Specifies the width of the test pulse. |
Sampling Times(Time) |
For In-Service Mode,
For Out-of-Service Mode,
|
Specifies the total sampling times. |
Sampling Frequency(MHz) |
For example: 5 |
Indicates the query result of the sampling frequency. |
LMI Optical Power(dBm) |
For example: -60 |
Indicates the query result of LMI Optical Power. |
Code Pattern |
For the SLM 1630 V100R001: Single, Short, Medium, Long Default: Single For the SLM 1630 V100R002: Single |
Specifies the code pattern of the test pulse. |
Testing Time(Hour:Minute:Second) |
For example: 01:15:08 |
Specifies the total time of the test. |
Optical Power(dBm) |
For In-Service Mode,
For Out-of-Service Mode,
|
Indicates the query result of the detection optical power. |
Dummy Laser Status |
Open, Close |
Specifies the status of the dummy laser.
NOTE:
This parameter can be set only in Out-of-Service mode. |
Dummy Laser Band Type |
C |
Specifies the band type of the dummy laser.
NOTE:
This parameter can be set only in Out-of-Service mode. |
Dummy Laser Wavelength NO./Wavelength (nm)/Frequency (THz) |
For example: 44/1546.12/193.900 |
Specifies the wavelength NO., wavelength and frequency of the dummy laser.
NOTE:
This parameter can be set only in Out-of-Service mode. |
Balance Dummy Light and Probe Light |
Yes, No |
Specifies whether the dummy light and the probe light is balanced.
NOTE:
|
Dummy Laser Power(dBm) |
1 to 7 |
Specifies the laser power of the dummy laser.
NOTE:
|