Auxiliary Interface

In this user interface, you can configure different modes for a port based on actual requirements.

Navigation Path

In the NE Explorer, choose Configuration > Auxiliary Interface from the Function Tree.

Parameters

Field

Value

Description

Port

slot number-board name-Port name

Displays the port name.

Interface Mode

1st external clock, 2nd external clock, 1st external time, 2nd external time, MON, Orderwire, S1/F1, Commissioning serial port, External clock (Hz mode)+outdoor cabinet, EXT+S1, MON2, 16th E1

You can configure different modes for a port based on actual requirements.
  • 1st external clock: Indicates the port transmits the first channel external clock signals.
  • 2nd external clock: Indicates the port transmits the second channel external clock signals.
  • 1st external time: Indicates the port transmits the first channel synchronous time signals.
  • 2nd external time: Indicates the port transmits the second channel synchronous time signals.
  • MON: Indicates the port transmits monitoring signals.
  • Orderwire: Indicates the port transmits orderwire signals.
  • S1/F1: Indicates the port transmits synchronous or asynchronous data.
  • Commissioning serial port: Indicates the port works in serial port mode for NE commissioning.
  • External clock (Hz mode)+outdoor cabinet: Indicates the port can be used as an external time input/output port and to monitor the running status of the outdoor cabinet.
  • EXT+S1: Indicates the port can be used as an EXT port and to transmit synchronous data.
  • MON2: Indicates the port transmits orderwire signals.
  • 16th E1: Indicates the 16th E1 can be used as the 2 Mbit/s external clock port.

Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.