In this user interface, you can set parameters for performance detection, and start or stop performance detection.
In the NE Explorer, select an Ethernet board and choose from the Function Tree. Click .
Button |
Description |
|---|---|
Start Detect |
Starts performance detection to send detection packets to the destination maintenance point. |
Stop Detect |
Stops performance detection from sending test packets to the destination maintenance point. |
Field |
Value |
Description |
|---|---|---|
Send Mode |
Burst Mode, Continue Mode |
Specifies a mode in which performance detection packets are sent. |
Frame Length |
64 to 1522 bytes |
The length of a performance detection packet. |
Timeout |
3 to 60 seconds |
The timeout time. |
| Detect Attempts | 1-1000, in step length of 1 Default: 1 |
The Detect Attempts parameter specifies the detection attempts for performing performance detection defined in IEEE 802.1ag. |
Source MP ID |
For example: 00-00-0001 |
The ID of the maintenance point that sends detection packets. |
Destination MP ID |
For example: 00-00-0002 |
The ID of the maintenance point that receives detection packets. |
Detail |
- |
The information returned after you perform performance detection. |