Working Mode

In this user interface, you can set working modes of the board and ports on the board.

Navigation Path

In the NE Explorer, select a board, and choose Configuration > Working Mode from the Function Tree.

Parameters

Field

Value

Description

Board Working Mode

  • 52TOM: Cascading, Non-Cascading
  • ELOM (Compatible Mode): 1*AP8 ODU1 mode, 1*AP4 ODU1 mode, 1*AP1 ODU2 mode, 1*AP2 ODU2 mode, 1*AP8 ODU0&ODU1 mode
  • ELOM (Standard Mode): 1*AP8 general mode, 1*AP1 ODU2 mode, 1*AP1 ODUflex mode
  • F1ELQM: 1*AP4 ODU1 mode, 1*AP2 ODU0 mode
  • F2LQM: 1*AP4 ODU1 mode, 1*AP2 ODU0 mode, 1*AP2 REG mode
  • F2LDGF2: 2*AP2 ODU0 mode, 2*AP2 ODU1 mode
  • F1LQM2: 2LQM mode, AP8 mode
  • F2LQM2: 2LQM2 mode, AP8 mode, 2*AP2 ODU0 mode, 2*AP3 ODU1 mode

Sets the working mode of the board.

Optical Port

For example: NE(9-21)-shelf0(subrack)-3-52TOM-201(ClientLP1/ClientLP1)

Displays the name of the optical interface.

Port Working Mode

52TOM:
  • In the Cascading mode:
    • ODU0 mode (Any->ODU0[->ODU1])
    • ODU0 tributary-line mode (Any->ODU0->ODU1->OTU1)
    • ODU1 mode (OTU1/Any->ODU1)
    • ODU1 tributary-line mode (OTU1/Any->ODU1->OTU1)
    • None (not for ports)
  • In the Non-Cascading mode:
    • ODU0 mode (Any->ODU0[->ODU1])
    • ODU0 tributary-line mode (Any->ODU0->ODU1->OTU1)
    • ODU1 mode (OTU1/Any->ODU1)
    • ODU1_ODU0 mode (OTU1->ODU1->ODU0)
    • ODU1_ANY_ODU0 re-encapsulation mode (OTU1->ODU1->Any->ODU0)
    • ODU1_ANY_ODU0_ODU1 re-encapsulation mode (OTU1->ODU1->Any->ODU0->ODU1)
    • ODU1_ANY_ODU0_ODU1 re-encapsulation tributary-line mode (OTU1->ODU1->Any->ODU0->ODU1->OTU1)
    • ODU1 tributary-line mode (OTU1/Any->ODU1->OTU1)
    • None (not for ports)
54TEM28:
  • ClientLP1 to ClientLP8:
    • ODU0 non-convergence mode (Any->ODU0)
    • None (not for ports)
  • ClientLP9 to ClientLP16:
    • ODU0 non-convergence mode (Any->ODU0)
    • ODU1 non-convergence mode (OTU1/Any->ODU1)
    • ODU2 non-convergence mode (OTU2/Any->ODU2)
    • ODUflex non-convergence mode (Any->ODUflex)
    • None (not for ports)

ELOM (Compatible Mode):

In the 1*AP8 ODU0&ODU1 mode:
  • ODU0 non-convergence mode (Any->ODU0[->ODU1]->ODU2->OTU2)
  • ODU1 non-convergence mode (OTU1/Any->ODU1->ODU2->OTU2)
  • None (not for ports)

ELOM (Standard Mode):

Common mode:
  • ODU0 non-convergence mode (Any->ODU0)
  • ODU1 convergence mode (n*Any->ODU1)
  • ODU1 non-convergence mode (OTU1/Any->ODU1)
  • ODUflex non-convergence mode (Any->ODUflex)
  • None (not for ports)

F1ELQM and F2LQM:

1*AP4 ODU1 mode:
  • ODU1 convergence mode (n*Any->ODU1)
  • ODU1 non-convergence mode (OTU1/Any->ODU1)

F2LQM2:

when the Board Working Mode is 1*AP8 ODU1 mode, 2*AP4 ODU1 mode, 2*AP2 ODU0 mode or 2*AP3 ODU1 mode:
  • ODU1 convergence mode (n*Any->ODU1)
  • ODU1 non-convergence mode (OTU1/Any->ODU1)

Sets the working mode of the port on the board.

NOTE:
  • [->**] indicates that this segment is optional. For example, in the case of the ODU0 tributary mode of the non-cascading mode, there are two paths of processing services as follows: Any->ODU0 and Any->ODU0->ODU1.
  • If the None mode is selected, the resources of the port are not used and are released for other ports.

Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.