In this user interface, you can perform an in-service PRBS test for a board of WDM equipment. The test result is displayed in the coordinates pane.
In the NE Explorer, click a board and choose from the Function Tree.
The PRBS test will interrupt the service.
A PRBS test is used only in deployment. After the deployment, set PRBS Test Status to Disabled.
Button |
Description |
|---|---|
Query |
Queries PRBS test results and displays the results in the graph. The query operation provides only
the latest summary result of the test and refreshes the diagram accordingly.
The intermediate results will be lost.
|
Start to Test |
Start the PRBS test. |
Stop to Test |
Stop the PRBS test. |
Item |
Description |
|---|---|
Clear Result |
Clears the PBRS test result. |
Field |
Value |
Description |
|---|---|---|
Port |
|
Displays the port. |
Duration |
1 to 255 |
Sets the test duration. |
Measured in Time |
s, 10min, h |
Sets the test time unit. NOTE:
Currently, the following PRBS tests are available: short-time test, long-time test, and extra-long-time test.
|
Start Time |
Year-Month-Date Hour:Minute: Second |
Specifies the test start time. |
Progress |
For example: 5% |
Specifies the test progress. |
Total PRBS |
For example: 0 |
Specifies the total number of bit errors during PRBS test. |
Accumulating Mode |
Checked, Unchecked |
Checks this check box to enable the accumulating display. NOTE:
In a cumulative mode, the bit error value in the n second is the sum of the bit errors in the previous n seconds. |