In this user interface, you can manage optical power for boards, and set optical power reference value.
In the NE Explorer, select a board and choose from the Function Tree.
Field |
Description |
|---|---|
Port/Path |
Displays the port information. For example: NE75-Shelf1(slave shelf5)-1-LOE-1(IN1/OUT1)-1 |
Input Power(dBm) |
Displays the optical power value of the receiving port. Double-click this item to set the optical power of the receiving port. |
Input Power Lower Threshold(dBm) |
Displays the lower threshold of Input Power(dBm). If the value of Input Power(dBm) is smaller than this value, an alarm is generated. |
Min. Value of Input Power Lower Threshold(dBm) |
Displays the minimum value of Input Power Lower Threshold(dBm). The value of Input Power Lower Threshold(dBm) must be greater than or equal to this value. |
Max. Value of Input Power Lower Threshold(dBm) |
Displays the maximum value of Input Power Lower Threshold(dBm). The value of Input Power Lower Threshold(dBm) must be smaller than or equal to this value. |
Input Power Upper Threshold(dBm) |
Displays the upper threshold of Input Power(dBm). If the value of Input Power(dBm) is greater than this value, an alarm is generated. |
Min. Value of Input Power Upper Threshold(dBm) |
Displays the minimum value of Input Power Upper Threshold(dBm). The value of Input Power Upper Threshold(dBm) must be greater than or equal to this value. |
Max. Value of Input Power Upper Threshold(dBm) |
Displays the maximum value of Input Power Upper Threshold(dBm). The value of Input Power Upper Threshold(dBm) must be smaller than or equal to this value. |
CFP Input Power Lower Threshold(dBm) |
Sets the lower threshold of CFP input power. If the value of input power is smaller than this value, an alarm is generated. |
Min. Value of CFP Input Power Lower Threshold(dBm) |
Displays the minimum value of CFP Input Power Lower Threshold(dBm). The value of CFP Input Power Lower Threshold(dBm) must be greater than or equal to this value. |
Max. Value of CFP Input Power Lower Threshold(dBm) |
Displays the maximum value of CFP Input Power Lower Threshold(dBm). The value of CFP Input Power Lower Threshold(dBm) must be smaller than or equal to this value. |
CFP Input Power Upper Threshold(dBm) |
Sets the upper threshold of CFP input power. If the value of input power is greater than this value, an alarm is generated. |
Min. Value of CFP Input Power Upper Threshold(dBm) |
Displays the minimum value of CFP Input Power Upper Threshold(dBm). The value of CFP Input Power Upper Threshold(dBm) must be greater than or equal to this value. |
Max. Value of CFP Input Power Upper Threshold(dBm) |
Displays the maximum value of CFP Input Power Upper Threshold(dBm). The value of CFP Input Power Upper Threshold(dBm) must be smaller than or equal to this value. |
Max. Pump Output Power (dBm) |
Displays the maximum value of pump output optical power. |
Min. Pump Output Power (dBm) |
Displays the minimum value of pump output optical power. |
Output Power(dBm) |
Displays the optical power value of the transmitting port. Double-click this item to set the optical power of the transmitting port. |
CFP Current Valley Input Power(dBm) |
Query the minimum single-wavelength input optical power of the current channel on the CFP module. |
CFP Current Peak Input Power(dBm) |
Query the max single-wavelength input optical power of the current channel on the CFP module. |