In this user interface, you can set parameters for protection boards. The parameters are laser status, automatic laser shutdown, maximum or minimum attenuation rate and path use status.
Field |
Value |
Description |
|---|---|---|
Optical Interface/Channel |
|
Displays the optical interface. |
Optical Interface Name |
For example: RI1/TO1 |
Displays the default names. Do not modify this field. |
Threshold of Input Power Loss (dBm) |
Values of parameters vary with different boards and products. For details, click the links in the Description column. | Sets the threshold of the optical power loss. When the input optical power is below this value, the loss of input signals occurs. |
Initial Variance Value Between Primary and Secondary Input Power (dB) |
-10.0 to 10.0 |
Sets the initial variance value between primary and secondary input power. |
Variance Threshold Between Primary and Secondary Input Power (dB) |
3.0 to 8.0 |
Sets the variance threshold between primary and secondary input power. |