In this user interface, you can decide whether the clock signal that the equipment outputs through the clock interface contains SSM messages.
In the NE Explorer, choose . Click the SSM Output tab.
Parameter |
Value |
Description |
|---|---|---|
Line Port |
For example: Internal Clock Source 1 |
Indicates the line port name. |
Other Fiber End |
For example: NE2-Shelf18(subrack)-18-11ST2-2(RM2/TM2) |
Indicates the port connected to the line port by a fiber. |
Output S1 Byte Info |
Enabled, Disabled |
Specifies whether to set the clock source outputs the S1 byte quality information or not. It is usually set to Disabled at the boundary of a clock network. For example, in the case of interconnection with a network formed by equipment of other vendors, you can set it to Disabled at the boundary of a clock network to avoid impact on other equipment. In general, it is set to Enabled. |