In this user interface, you can query and set clock source switching conditions, and the status of switching condition enabling.
In the NE Explorer, choose . Click the Clock Source Switching Conditions tab.
Parameter |
Value |
Description |
|---|---|---|
Clock Source |
For example: Internal Clock Source |
Indicates the name of the clock source. |
OTU2_DEG Alarm |
Yes, No Default: No |
Specifies the switching condition enabling status. When an OTU2_DEG alarm occurs in the NE, the NE regards that the corresponding clock source fails. |
OTU3_DEG Alarm |
Yes, No Default: No |
Specifies the switching condition enabling status. When an OTU3_DEG alarm occurs in the NE, the NE regards that the corresponding clock source fails. |
ODU2_PM_AIS Alarm |
Yes, No Default: No |
Specifies the switching condition enabling status. When an ODU2_PM_AIS alarm occurs in the NE, the NE regards that the corresponding clock source fails. |
ODU2_PM_DEG Alarm |
Yes, No Default: No |
Specifies the switching condition enabling status. When an ODU2_PM_DEG alarm occurs in the NE, the NE regards that the corresponding clock source fails. |
ODU3_PM_AIS Alarm |
Yes, No Default: No |
Specifies the switching condition enabling status. When an ODU3_PM_AIS alarm occurs in the NE, the NE regards that the corresponding clock source fails. |
ODU3_PM_DEG Alarm |
Yes, No Default: No |
Specifies the switching condition enabling status. When an ODU3_PM_DEG alarm occurs in the NE, the NE regards that the corresponding clock source fails. |
MS_AIS Alarm |
Yes, No Default: No |
Specifies the switching condition enable status. When an MS_AIS Alarm alarm occurs in the NE, the NE regards that the corresponding clock source fails. |
B2_EXC Alarm |
Yes, No Default: No |
Specifies the switching condition enabling status. When an B2_EXC alarm occurs in the NE, the NE regards that the corresponding clock source fails. |