Provisioning Orderwire

To provide the maintenance personnel with a dedicated express orderwire channel, you can configure orderwire for NEs.

Prerequisites

  • The EOW board must be created.
  • It is applicable to the NS3 board that support the orderwire function on the OptiX BWS 1600S T16.

Procedure

  1. In the NE Explorer, select an NE and choose Configuration > Orderwire from the Function Tree. Click the General tab.
  2. Click Query to query information from the NE.
  3. Set Call Waiting Time (s), Telephone No. and orderwire ports.

    NOTE:
    • Call Waiting Time (s) should be set to the same value for all NEs with orderwire communication. When the number of NEs is smaller than 30, set the value to 5 seconds. Otherwise, set it to 9 seconds.
    • The telephone number cannot repeat in the same orderwire subnet.
    • Set the length of the telephone number according to the actual requirements. The maximum length is eight digits and the minimum length is three digits. In the same orderwire subnet, the number length must be the same.
    • The length of the telephone number must be the same as that of the conference call number.
    • If the length of the subnet number is 1, the first digit of the two orderwire numbers must be the same. If the length of the subnet number is 2, the first two digits of the two orderwire numbers must be the same.

  4. Click Apply.

Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.