Application of IP over DCC

In the IP DCN solution, NEs use unified DCCs to transmit TCP/IP protocol data, which enables the U2000 Web LCT to manage the NEs.The IP DCN solution is applicable to a network consisting of only OptiX transmission equipment or a network consisting of OptiX transmission equipment and the third-party equipment that supports the IP DCN function. This solution is also applicable when the equipment located in the center of a network needs to provide IP-based network management message transmission paths for the equipment at the edge of the network.

Application 1: Gateway NE Mode

If the U2000 Web LCT and the GNE connect to the same Ethernet (the U2000 Web LCT and the GNE need to be in the same subnet), and other NEs are accessed in the gateway NE mode, you do not need to add any static routes.

As shown in Figure 1, the U2000 Web LCT with the IP address of 129.9.0.100 uses the nearby NE1 as the GNE to access other NEs. You need not to add static routes on the U2000 Web LCT or NEs.

Figure 1 Gateway NE mode

Application 2: Gateway NE Mode (by Default Gateway)

If the U2000 Web LCT is connected to the GNE through a router and other NEs are accessed in the gateway NE mode, you need to add a default gateway on the U2000 Web LCT and on the GNE.

As shown in Figure 2, the U2000 Web LCT with the IP address 10.100.11.12 connects with the GNE (NE1) through a router and accesses other NEs in the gateway NE mode. In this case, you need to set a default gateway on both the U2000 Web LCT and NE1. Set the default gateway on the U2000 Web LCT to 10.100.11.1, and that on NE1 to 129.9.0.254.

Figure 2 Gateway NE mode (by default gateway)

Application 3: Direct Connection Mode (by Static Routes)

If the U2000 Web LCT and the GNE connect to the same Ethernet and other NEs are accessed in the direct connection mode, you need to set on the U2000 Web LCT the default gateway to the IP address of the NE that is connected to the U2000 Web LCT directly. Or you need to add the static route to the non-GNEs, with the forwarding address as the IP address of the GNE.

As shown in Figure 3, if the U2000 Web LCT with the IP address of 129.9.0.100 needs to access NE3 directly, you need to add the static route to 133.168.0.0/24 on the U2000 Web LCT.

Figure 3 Direct connection mode (by static routes)

Application 4: Direct Connection Mode through a Router (by Static Routes)

The U2000 Web LCT connects to the Ethernet port of a certain NE through a router and accesses other NEs in the direct connection mode. You need to perform the following operations.

As shown in Figure 4, the U2000 Web LCT with the IP address of 10.100.11.12 connects to NE1 through a router and accesses NE3 in the direct connection mode. Suppose the IP address of the U2000 Web LCT is 10.100.11.0 (subnet mask 255.255.255.0). Perform the listed operations:

Figure 4 Direct connection mode through a router (by static routes)

Configuration Requirements

If NEs communicate with each other through IP over DCC, note the following rules for setting the network scale. It is recommended that a GNE manage no more than 50 and 60 non-gateway NEs (including the extended ECC).